EasyManua.ls Logo

Vacon 100 X - Page 98

Vacon 100 X
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
vacon • 95 Options
8.2.7.2 Fault codes
Fault
code
Fault
ID
Fault name Possible cause Remedy
1
1
Overcurrent
(hardware fault)
AC drive has detected too high a cur-
rent (>4*I
H
) in the motor cable:
sudden heavy load increase
short circuit in motor cables
unsuitable motor
Check loading.
Check motor.
Check cables and connections.
Make identification run.
Check ramp times.
2
Overcurrent
(software fault)
2
10
Overvoltage
(hardware fault)
The DC-link voltage has exceeded the
limits defined.
too short a deceleration time
brake chopper is disabled
high overvoltage spikes in supply
Start/Stop sequence too fast
Make deceleration time longer.
Use brake chopper or brake
resistor (available as options).
Activate overvoltage controller.
Check input voltage.
11
Overvoltage (soft-
ware fault)
3
20
Earth fault (hard-
ware fault)
Current measurement has detected
that the sum of motor phase current is
not zero.
insulation failure in cables or
motor
Check motor cables and motor.
21
Earth fault (soft-
ware fault)
540
Charging switch
The charging switch is open, when the
START command has been given.
faulty operation
component failure
Reset the fault and restart.
Should the fault re-occur, con-
tact the distributor near to you.
760
Saturation
Various causes:
defective component
brake resistor short-circuit or
overload
Cannot be reset from keypad.
Switch off power.
DO NOT RE-CONNECT POWER!
Contact factory.
If this fault appears simultane-
ously with F1, check motor
cables and motor.
Table 32. Fault codes and descriptions.