BOILER INSTALLATION SEQUENCE
Gas supply
(TURBOmax Plus)
Connect the 15 mm compression
gas service cock (1) and 15 mm
copper outlet tail (3) as supplied
with the appliance (2) and tighten.
Connect a gas supply pipe of not
less than 15 mm diameter to the
copper tail.
Tighten all connections.
(Ensure the gas supply pipework is
adequately sized such that a 20
mbar gas pressure is available at
the boiler inlet at full flow rate).
I
0
3
1
2
Euro B/S 046/0GB
Fig. I.6: Fitting the gas connection TURBOmax Plus
TURBOmax Plus