EasyManuals Logo

Vaillant TURBOmax Plus SERIES User Manual

Vaillant TURBOmax Plus SERIES
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
77
FAULT FINDING
Fault codes
Fault codes take priority over all other
display functions in the event of a
system fault occurring.
If multiple faults occur, the
corresponding fault codes are
displayed alternately for about two
seconds each.
Fault memory
The fault memory stores details of the
ten most recent faults.
Press the „i“ and „-“ buttons
simultaneously.
Use the „+“ button to scroll back
through the list of memorised
errors.
To cancel fault error memory display
mode, proceed as follows:
Press the „i“ button below the
display.
or
Do not touch any key for about
four minutes. The display will now
revert back to showing the current
flow temperature.
Display Indication Cause
F.00
Flow-NTC:
- NTC broken
- NTC cable broken
- Defective connection at NTC
- Defective connection at electronics
Flow-NTC cable defective/broken NTC faulty
F.01
Return-NTC:
- NTC broken
- NTC cable broken
- Defective connection at NTC
- Defective connection at electronics
Return-NTC cable defective/broken NTC faulty
F.11 Short circuit - return-NTC (< 130 °C)
NTC- plug shorted to casing
NTC defective
F.10 Short circuit - flow-NTC (< 130 °C)
NTC- plug shorted to casing
NTC defective
F.42 Faulty cable loom Faulty or incorrect loom fitted
F.43 Faulty cable loom Faulty or incorrect loom fitted
F.20 Over heat cut off activated Maximum temperature exceeded
F.22 Low water or no water in appliance
No water in system
Pump defective
Pump lead defective
F.27 no demand to gas valve
Electronic board defective
Gas valve defective
F.28 Boiler goes to lock out
No gas
Insufficient gas
Incorrect gas valve adjustment
Electrode defective
Ignition lead defect
Electronic igniter defective
F.29 Flame extinguished re-ignition unsuccessful Gas supply absent or insufficient
F.60 to F.67 Irreversible electronic system malfunction Electronic system defective
Table St.4: Fault codes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant TURBOmax Plus SERIES and is the answer not in the manual?

Vaillant TURBOmax Plus SERIES Specifications

General IconGeneral
CategoryBoiler
ModulationYes
ModelTURBOmax Plus SERIES
Fuel typeNatural gas
MountingWall-mounted
Heating CircuitSingle
Output24kW, 28kW
Warranty2 years (extendable)

Related product manuals