FAULT FINDING
Display Indication Displayed values/adjustment values
d.37 Modulator current mA
d.40 Actual flow temperature °C
d.45 Not applicable
d.47 Not applicable
d.50 Maximum flow temperature °C
d.53 Not applicable
d.54 Not applicable
d.60 Number over heat cut off operations
d.61 Number of lock outs
d.64 Average ignition time s
d.65 Maximum ignition time s
d.67 Remaining anti cycling period min
d.68
Number of unsuccessful attempted
1
st
ignitions
d.69
Number of unsuccessful attempted 2
nd
ignitions
d.72*
Pump over run (for loading warmstart or
Vantage cylinders)
0, 1, 2, … 250 s (factory-adjusted to: 80 s)
d.74 Not applicable
d.75
Maximum hot water priority operation time
(Vantage only)
20, 21, 22 … 90 min (factory-adjusted to: 30 min)
d.71
Maximum target value for heating system
flow temperature
0 = 82 ° C
1 = 87 °C (factory setting: 82 °C)
d.80**
Number of heating system operating hours
(Total)
h
d.81*
Number of hot water system operating
hours (Total)
h
d.82 Number of heating system cycles (Total)
d.83* Number of hot water system cycles (Total)
d.90 Not applicable
d.91 Not applicable
Table St.3: Diagnostic Modes 2 of 2 * TURBOmax Plus ** THERMOcompact
d.46 Not applicable
d.73* Offset warmstart temperature value -15, -14.......+5 K (factory-adjusted -15 K)