EasyManua.ls Logo

Vaillant TURBOmax Plus SERIES - Page 47

Vaillant TURBOmax Plus SERIES
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
GAS SUPPLY ADJUSTMENTS
(COMMISSIONING PART II)
1 Simultaneously press the „i” and
+” buttons keys.
2 Keep the „+” button pressed until
d.0” is displayed.
(The display runs from „d.0” to
d.99” before restarting again at
d.0”.)
3 Press the „i” button and a value
between 1 and 15 will be
displayed.
~ 5 s
5 After setting, press and hold the
i” button for five seconds - or until
the display stops flashing. The new
setting value is now memorised.
The new main burner pressure can
now be checked.
If the new output is not correct
repeat steps 3 to 5.
6 To return to normal mode, press
the „i” and „+” buttons
simultaneously.
The adjustment mode is also
cancelled if no button is pushed for
a period of four minutes.
4 Use the „+” or „-” buttons to
increase or decrease the value.
Observe the U-gauge as the button
is pushed and stop pushing when
the required main burner pressure
has been achieved.
Euro B/S 065/0
Euro B/S 066/0
Euro B/S 067/0
Euro B/S 068/0
Euro B/S 069/0
Euro B/S 065/0

Table of Contents