51
GAS SUPPLY ADJUSTMENTS
(COMMISSIONING PART II)
Gas Rate THERMOcompact 615/2 E
Natural gas 2H
Main burner jet mark
2)
7/120
Gas Rate
1)
[m
3
/h]
Delivered gas
for G20
Output [kW]
6.5 8.0 10.0 12.0 14.0 15.0
0.8 1.0 1.3 1.4 1.7 1.7
Gas Rate THERMOcompact 620/2 E
Natural gas 2H
Main burner jet mark
2)
7/120
Gas Rate
1)
[m
3
/h]
Delivered gas
per G20
Output [kW]
7.7 8.0 10.0 12.0 14.0 16.0 18.0 20.0
0.9 1.0 1.2 1.4 1.7 1.9 2.1 2.3
1)
15 °C, 1013 mbar, dry
2)
The nozzles are stamped with the mark shown in
this table. The marking corresponds to the nozzle
hole diameter multiplied by 100.
Table G.4: Gas flow rate
Gas Rate THERMOcompact 624/2 E, TURBOmax Plus 824/2 E
Natural gas 2H
Main burner jet mark
2)
7/120
Gas Rate
1)
[m
3
/h]
Delivered gas
for G20
Output [kW]
10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0
1.2 1.4 1.7 1.9 2.1 2.4 2.6 2.8
Gas Rate THERMOcompact 628/2 E, TURBOmax Plus 828/2 E
Natural gas 2H
Main burner jet mark
2)
7/120
Gas Rate
1)
[m
3
/h]
Delivered gas
per G20
Output [kW]
14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0
1.7 1.9 2.1 2.4 2.6 2.8 3.1 3.3
8.9
1.1
12.0
1.5
10.4
1.3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant TURBOmax Plus SERIES and is the answer not in the manual?

Vaillant TURBOmax Plus SERIES Specifications

General IconGeneral
CategoryBoiler
ModulationYes
ModelTURBOmax Plus SERIES
Fuel typeNatural gas
MountingWall-mounted
Heating CircuitSingle
Output24kW, 28kW
Warranty2 years (extendable)

Related product manuals