EasyManua.ls Logo

Vaisala Indigo500 Series - Output Options; Analog Outputs; Digital Output

Vaisala Indigo500 Series
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ANALOG OUTPUTS
RELAY 1RELAY 2
+
+
+
+
+
+
+
+
+
CH1
CH2
CH3
CH4
RS-485
PROBE
24 VOUT
ANALOG
INPUT
NO COM NC NO COM NC
1
2
VS
+
1
2
For the M16×1.5 cable glands ordered
together with the transmitter from Vaisala,
the cable diameter is 2.0 … 6.0 mm
(0.08 … 0.24 in). Tightening torque for the
cable gland is 6 Nm.
The recommended maximum length of the
probe cable is 30 m (98 ft).
1 Probe 1 lead-through, M16×1.5
2 Probe 2 lead-through, M16×1.5
Table 9 Connection terminals for probe 1 and probe 2
Terminal Function Wire color in Vaisala
cables
Notes
RS-485- RS-485- White
Max. wire size: 2.5 mm
2
(14 AWG)
RS-485+ RS-485+ Black
24 VOUT - Power GND and
RS-485 common
Blue
24 VOUT + Positive supply voltage to
probe
Brown
Verifying tightness of cable glands
To maintain enclosure tightness and provide strain relief to the cables, all cable glands must be
tightened. Unused cable glands must remain plugged.
1. Check every cable gland that is in use:
a. Pull on the cable to verify that the cable is securely held by the cable gland.
b. Tighten the cable gland if the cable moves.
2. Check that every unused cable gland is plugged and tightened.
17