EasyManua.ls Logo

Vaisala WXT536 - Table 19 Transducer Ids of Measurement Parameters

Vaisala WXT536
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 ___________________________________________________ Retrieving Data Messages
VAISALA______________________________________________________________________ 119
Example of the XDR Query (all parameters of each sensor enabled
and NMEA wind formatter set to T):
$--WIQ,XDR*2D<cr><lf>
Example of the response when all the parameters of each sensor are
enabled (NMEA wind formatter set to T):
Wind sensor data
$WIXDR,A,302,D,0,A,320,D,1,A,330,D,2,S,0.1,M,0,S,0.2,M,1,S,0.2,
M,2*57<cr><lf>
Table 19 Transducer IDs of Measurement Parameters
Measurement Transducer ID Type
Wind direction min 0 A
Wind direction average 1 A
Wind direction max 2 A
Wind speed min 0 S
Wind speed average 1 S
Wind speed max 2 S
Pressure 0 P
Air temperature 0 C
Internal temperature 1 C
Relative humidity 0 H
Rain accumulation 0 V
Rain duration 0 Z
Rain current intensity 0 R
Hail accumulation 1
Hail duration 1
Hail current intensity 1
Rain peak intensity 2
Hail peak intensity 3
Heating temperature 2
Supply voltage 0 U
Heating voltage 1 U
3.5 V reference voltage 2
Information field 4
Aux. rain (tipping bucket) 1 V
Solar radiation 3
Snow level 4
Aux. temperature (pt1000) 3 C

Table of Contents