EasyManua.ls Logo

Vaisala WXT536 - Table 12 Screw Terminal Pin-Outs for Serial Interfaces and Power

Vaisala WXT536
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User’s Guide ______________________________________________________________________
66 __________________________________________________________________ M211840EN-C
Table 12 Screw Terminal Pin-outs for Serial Interfaces and
Power Supplies
Screw
Terminal PIN
RS-232 SDI-12 RS-485 RS-422 mA Output
1 VIN+ Vin+
(Operating)
Vin+
(Operating)
Vin+
(Operating)
Vin+
(Operating)
Vin+
(Operating)
2 VIN- Vin- (Operating
GND)
Vin- (Operating
GND)
Vin- (Operating
GND)
Vin- Operating
GND)
Vin- (Operating
GND)
3 RX- Data- Data in (RX-)
4 RX+ Data+ Data in (RX+)
5 TX- Data out (TxD) Data in/out (Tx) Data- Data out (TX-) Iout1
6 TX+ Data+ Data out (TX+) GND
7 RXD Data in (RxD) Data in/out (Rx) Iout2
8 SGND Communication
ground (GND)
Communication
ground (GND)
Communication
ground (GND)
GND
9 HTG+ Vh+ (Heating) Vh+ (Heating) Vh+ (Heating) Vh+ (Heating) Vh+ (Heating)
10 HTG- Vh- (Heating) Vh- (Heating) Vh- (Heating) Vh- (Heating) Vh- (Heating)
NOTE
Use a shielded cable and ground the external wiring shield.
NOTE
For the SDI-12 mode, the Data in/out (Tx) and Data in/out (Rx) signals
must be connected internally by looping pins 5 and 7, or, externally by
looping the M12 pins 1 and 7.
NOTE
If the transmitter was ordered with any other serial communication
than RS-422, the internal wiring has loops between pins 3 and 5, and
between 4 and 6. For RS-422 operation, you must remove the loops.
For the RS-485 communication mode, short-circuit jumpers are
required between pins 3-5 and 4-6.
3 = RX- Data- Loop with Blue
4 = RX- Data- Blue
5 = RX+ Data+ Loop with Gray
6 = TX+ Data+ Gray
The transmitter has by default factory-installed loops in all serial
communication options except RS-422.

Table of Contents

Related product manuals