Appendix E _____________________________________________________ Factory configurations
VAISALA______________________________________________________________________ 205
PTU Configuration Settings
0TF!0TF,n=A0430432 <cr><lf>
Rain Configuration Settings
0RF!0RF,p=1.0,n=3.0,d=N,f=0<cr><lf>
Supervisor Settings
0SF!0SF,t=19.8,b=17159,l=-4.0,m=0.0,h=4.0<cr><lf>
Table 44 PTU Configuration Settings
Field Character Field Name Description
n PTU serial number A,B,...=2005,2006..., 1..52 =
week, 1...7 = weekday , 1...9999
= serial number
Table 45 Rain Configuration Settings
Field Character Field Name Description
p,n Positive and negative gain 0.1...25.5 (p=1.0, n=1.0)
d Bypass all hits Y=Enabled, N=(default)
Disabled
f Wind filter bypass 0,1...4 (0=wind depended,
1,2,3,4=threshold level)
Table 46 General Unit Settings
Field Character Field Name Description
t CPU temperature calibration temperature °C
b Direct ADC value of CPU temperature diode 0 ... 4096
l Heater control gain -100.0 ...[m] °C (default -4.0 °C)
m Heating set point °C
h Not used