Appendix F __________________________________________ Wiring External Sensors to WXT536
VAISALA______________________________________________________________________ 215
Connecting Rain Gauge to WXT536
The following figure shows how to wire rain gauge RG13 to WXT536.
1510-005
Figure 54 Wiring RG13 to WXT536
To wire RG13 to WXT536:
- Connect the green wire (additional sensor connector pin number 4)
to the screw terminal 7.
- Connect the grey wire (additional sensor connector pin number 5)
to the screw terminal 8.
1 = Cable tie
2 = Screw terminal 8
3 = Screw terminal 7
4 = Cable shield
5 = Grounding point