User’s Guide ______________________________________________________________________
226 _________________________________________________________________ M211840EN-C
Test
message
0 For test purposes XU,T
Serial
interface
Order
option
defined
1 = SDI-12
2 = RS-232
3 = RS-485
4 = RS-422*
*Note that RS-422 hardware
is wired differently inside the
unit.
XU,C
Repeat
interval in
seconds
0 0 ... 3600 seconds XU,I
Baud rate Order
option
defined
1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200
Bauds
XU,B
Data bits Order
option
defined
7, 8 XU,D
Parity Order
option
O = Odd, E = Even, N = None XU,P
Stop bits Order
option
defined
1, 2 XU, S
RS-485
delay
25 0 ... 10000 ms XU,L
Device
name
Order
option
defined
WXT531 ... WXT536 Read-only XU,N
Software
version
3.xx 3.xx Read-only XU,V
Table 50 General Parameters