Home
VAMP
Protection Device
220
Page 68
VAMP 220 - Page 68
68 pages
Manual
Save Page as PDF
To Previous Page
To Previous Page
Loading...
VM220.EN004
VAMP
Lt
d
Street address
:
Runsorintie 7
Phone: +358 6 212 1100
Post address:
Fax: +358 6 212 1105
Box 5, FIN 65381 Vaasa,
In
terne
t:
ww
w.vam
p.fi
Finland
Email:
vam
p@v
am
p.
fi
We res
erv
e the righ
ts to c
hang
es wi
thou
t prio
r noti
ce
67
Table of Contents
Main Page
Default Chapter
3
Table of Contents
3
Preface
5
1 Introduction
6
2 System Description
8
Master Unit VAMP 220/220R
8
General
8
Functional Description
9
Slave Unit VAM 12 CD
11
Arc Sensor VA 1 da
12
Portable Sensor VA 1 DP
13
Trip Multiplier Relay VAR 4 CE
14
Systems with Multiple Master Units
15
Selective Arc Protection
15
3 Technical Data
17
Master Unit VAMP 220/220R
17
Slave Unit VAM 12 CD
19
Arc Sensor VA 1 da
20
Portable Sensor VA 1 DP
20
Trip Multiplier Relay VAR 4 CE
20
4 Product Handling
21
Receiving Goods
21
Unpacking and Transportation
21
Checking the Consignment
21
Complaints
21
Warranty
21
5 System Installation
23
Safety Notes
23
Preparing for Installation
23
Installing Master Unit VAMP 220/220R
24
Mounting Master Unit VAMP 220/220R
24
Wiring the Master Unit, Overview
24
Wiring Secondary Circuits of Current Transformers
25
Wiring Trip Circuits of Circuit Breakers
26
Wiring Alarm Circuits
27
Protective Earthing
27
Wiring Auxiliary Supply
27
Installing Slave Units
29
Mounting Slave Unit VAM 12 CD
29
Wiring between Master and Slave
29
Wiring Separate Power Supply to VAM 12 CD
30
Installing Sensors
31
Mounting Arc Sensor VA 1 da
31
Connecting Sensors to Slave Units
32
Connecting Portable Sensor
33
Arc Sensor Wiring over Long Distances
33
Installing Trip Multiplier VAR 4 CE
33
Wiring Multiple Master Systems
35
Wiring Systems with Selective Arc Protection
36
Checking Wirings
36
Visual Inspection
36
Control by Measuring
37
6 Commissioning
38
Using Master Unit Control Panel
38
General
38
Control Modes
39
Fast Guide of the Function Menu
40
Push-Button Functions
41
Using Slave Unit Panel
41
Setting Addresses of Slave Units
42
System Configuration
43
Setting Overcurrent Values
45
Relay Output Settings
47
Testing the Arc Sensors
54
7 Operational Measures
55
Arc Faults
55
Arc Fault Tripping Alarm
55
Reading Arc Fault Information
55
Supervision of Phase Currents
56
Overcurrent Warning
56
Reading Current Values
56
Handling Self-Supervision Faults
57
Error Indications
57
Reading and Erasing Error Messages
58
Fault Codes
59
VAM 12 CD TEST/ERROR Indication
60
Checking System Configuration
61
8 Application Examples
62
System with Two Master Units
62
9 Product Information
63
Dimensional Drawing
63
Panel Mounting
64
Semi-Flush Mounting
64
Ordering Code VAMP220/220R
65
11 Reference Information
67
Related product manuals
VAMP 121
26 pages