VAMP 220 / 220R
Arc protection system
User manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the VAMP 220 and is the answer not in the manual?

VAMP 220 Specifications

General IconGeneral
Frequency50/60 Hz
Current Inputs3
Protection FunctionsOvercurrent, Voltage, Frequency
MountingDIN Rail
StandardsIEC 60255

Summary

System Description

Master Unit VAMP 220/220R Functional Description

Slave Unit VAM 12 CD Description

Arc Sensor VA 1 DA Details

Selective Arc Protection Example

Technical Data

Slave Unit VAM 12 CD Technical Specifications

Arc Sensor VA 1 DA Technical Data

System Installation Procedures

System Installation Safety Precautions

Provides essential safety notes and warnings to be observed during installation work.

Installing the Master Unit VAMP 220/220R

Master Unit Wiring Overview

Provides an overview of the required wirings for the master unit, including CTs, trip circuits, and auxiliary supply.

Wiring Master Unit Current Transformer Circuits

Wiring Master Unit Circuit Breaker Trip Circuits

Wiring Master Unit Alarm Circuits

Master Unit Protective Earthing Connection

Instructs on connecting the master unit to protective earth via the PE terminal.

Master Unit Auxiliary Supply Wiring

Details how to connect the auxiliary supply voltage to the master unit's input terminals.

Installing Slave Units

Wiring Between Master and Slave Units

Details how to connect the master unit and slave units using the VX 010 modular cable.

Wiring Separate Power Supply to Slave Units

Installing Arc Sensors

Connecting Sensors to Slave Units

Wiring Multiple Master Systems

Wiring for Selective Arc Protection

Checking Wiring Integrity

Outlines methods for checking wirings, including visual inspection and measuring.

Wiring Verification by Measuring

Commissioning Procedures

Using the Master Unit Control Panel

Guides users on navigating and operating the master unit's control panel.

Master Unit Control Modes

Function Menu Quick Guide

Master Unit Push-Button Functions

Setting Slave Unit Addresses

System Configuration Process

Verifying System Configuration

Setting Overcurrent Values

Reading Measured Currents in CURRENT Mode

Configuring Relay Output Settings

Master Unit Relay Setting Examples

Testing Arc Sensors and Data Transfer

Operational Measures

Handling Arc Faults

Describes how the system reports and logs arc fault tripping alarms.

Arc Fault Tripping Alarm Indication

Explains how tripping alarms are obtained via output contacts and indicated on the master unit control panel.

Reading Recorded Arc Fault Information

Details how to access stored arc fault data, including sensor addresses and BI/O line identifiers.

Phase Current Supervision

Overcurrent Warning Indication

Explains the warning code 200 displayed when phase currents exceed the start value.

Handling Self-Supervision Faults

Master Unit Error Indication and Fault Messages

Explains how the ERROR indicator and fault messages signal internal faults in the master unit.

Reading and Erasing Error Messages

Self-Supervision Fault Codes

Checking System Configuration