Boiling mode
●Temperature: 30°C - Boiling temperature
●Additional function: PowerBoost
Step Operation Note / Safety
A
Preconditions
●Lid must be detected in the up position
●Lid must be unlocked: (Pressure units)
●Pan must be detected in the down position
The heating is turned off if the angle of the
pan is > 12°
Pan valve closes* if detected open
B
Regulation
Regulation via:
Pan thermocouple (L: B1 / R: B2)
or core probe (L: B12 / R: B13)
The choice between the core probe and the
pan thermocouple is made based on the
highest temperature.
C
Regulation / lid closed
If the lid is no longer detected in the up position, then the maximum
temperature = [T° boiling -3°C]. Via pan thermocouple (L: B1 / R: B2)
or core probe (L: B12 / R: B13) Same conditions for selection as in
step B.
The heating is turned off if the angle of the
pan is > 12°
D
Complementary PowerBoost
function
Regulation of heating via heating thermocouples.
112G: B4 > B6 / 112D: B7 > B9
211/311: B4 > B11
Forthepressurecookermode,youwillndadetaileddescriptionoftheprocessinthepressuremodule.
* Only on devices equipped with a motorised pan valve.
XII.03
v03 • July-2016 • Hen
Cooking mode module
Line Units Serial number (starting from) Sw Revision
VCCM
VCCWE
112P, 211P, 311P ExxXH1009xxxxxxx 01-01-00