Series 200
200 to 218
Num. Compo-
nent
Conditions Diagnosis
200
VarioDose
Fill with water failed.
The VarioDose sensor meas-
ures less than 200 pulses in
20 sec.
●Check the water connection, opening the tap.
● The water ow must be at least 1.8 m3/hour.
●Check that the VarioDose sensor is not obstructed or
hampered by an impurity. If necessary check the condi-
tion of the water connection inlet lter.
●Check the connection of the sensor to the board.
●Check the proper functioning and the power to the
solenoid valves.
●Check the status of the klixon F25/F27 for units that are
tted with them.
201
VarioDose
Fill with water failed.
The VarioDose sensor meas-
ures less than 200 pulses in
20 sec.
207
B14 No heating R9
●Check the power to the unit (Presence of all phases
and neutral).
●Check the connections to the SSRs and between the
SSRs and the A4 board.
●Verify that no thermocouple is in error
●Check the preconditions for access to the cooking
mode (pan detected down, cover up, cover unlocked)
208
B15 No heating R10
209
B16 No heating R11
210
B17 No heating R12
211
B4 No heating R1
212
B5 No heating R2
213
B6 No heating R3
214
B7 No heating R4
215
B8 No heating R5
216
B9 No heating R6
217
B10 No heating R7
218
B11 No heating R8