USB
Service data: Description
Description of the content of the service le
«Setting» Section
It contains the advanced settings information of the device.
Field name Translation Note
Altitude Apliance instalation Altitude 300m steps
First start date / time Apliance rst start-up date and time
Altitude set date / time Altitudee setup date and time
2 years warranty enabled Extended warranty message display Yes / no
2 years warranty counter Remaining reminders about extended
warranty
1 ... 5
Warranty URL Displayed internet address for
extended warranty registration
Factory setting
Service phone Phone number displayed in case of a
service message
Factory setting
Chef line phone Phone number displayed to the cus-
tomer (Chef menu)
Factory setting
Flowmeter Flowmeter VarioDose setting 900 .... 1150
Diagnostic section, "Diag 1"
This contains information from the service mode about real-time temperature measurements.
For more information on the sensors see the "components" chapter.
Field name Translation Note
Sensor Thermocouple concerned B1... B17, B12.1... B12.6, B13.1...
B13.6
Actual Actual value 0 ... Max. Tol.
Max. Maximum value reached Yes / no
Unit Temperature measurement unit C° / F°
Max. Date / Time Date and time when the maximum
value was reached
Offset/Calib. Offset value obtained during the last
calibration
Min. Tol. / Max. Tol. Min.-Max. tolerance
v03 • July-2016 • Hen
V.08
Communication Module
Line Units Serial number (starting from) Sw Revision
VCCM
VCCWE
All ExxXH1009xxxxxxx 01-00-10