7.2.1 Replacement of shaft feedthrough seals and valve cleaning
7.2.1.1 Needed tools
Allen Wrench 2mm
Allen Wrench 3mm
Note: Sample pictures
Make sure that the valve is in closed position
Vent vacuum system, disconnect electrical connections and remove valve from vacuum
system. If you only replace control and actuating unit, the valve can remain in the
system.
Take care not to damage sealing surface! Do not move the plate by hands when
control an actuating unit is installed.
Depending on
flange screws
2. Unfasten clamp coupling
Unfasten the 2 connection bolts and separate both
parts.
Valve size DN 160 (6”) and bigger require a
shortened wrench. For ordering number refer to
«Spare parts and accessories».
4. Unfasten screws and remove plate from shaft.