Series 613 INSTALLATION
984360EC Edition 12.08.2022 55/
149
Sub Group Parameter ID [hex] Data Type
Acc
NV Unit Min Max Description
General
Settings
Profile Ramp Enable 07301801 BOOL RW
NV 0 1
Threshold Mode
07301802
UINT8
RW
NV
0
: Actual Pressure
1: Target Pressure Used
Ramp Type 07301840 UINT8 RW
NV 0:Linear
1:Logarithmic
2:Exponential
Actual Slope
07301841
FLOAT
R
-
mbar*/
sec
Controller Selector
Bitmap
07301811
UINT8
RW
NV
0
15
Selects controller which are used the Proifle Ramp
Segment Selector
Bitmap
07301810 UINT8 RW
NV 0 1023 Selects segments which are used in the profile
Segment x Threshold
07301820
FLOAT
RW
NV
mbar*
Defines the upper limit of a segment
10 Segments are available
Segment x Slope
07301830
FLOAT
RW
NV
mbar*/
sec
Define the slope in the segment
Adaptive
Learn
Start Learn 07501000 BOOL RW
V 0 1 Start learn procedure by setting to 1
Bank Selection 07500200 SINT8 RW
NV 0 3
Select a learn bank to safe the data for the following
learn procedure
0:Bank 1
1:Bank 2
2:Bank 3
3:Bank 4
Pressure Limit [SFS] 07500300 FLOAT RW
NV SFS 0.0001
1.2 Learn procedure will be executed to the Pressure
Limit
Pressure Limit 07500800 FLOAT RW
NV mbar*
See Pressure Limit [SFS] above, same functionality
but user pressure scalin
g
is used
Open Speed
07500400
FLOAT
RW
NV
0.001
1
1.0 equals to full speed
Status
07500600
SINT8
RO
V
0
4
0
:Not Started
1:In Progress
2:Completed Successfully
3:Aborted
4:Failed
Warning Info
07500700
UINT16
RO
V
Bit 1: Checksum error
Bit 2: Terminated by user
Bit 3: Unsuitable learn condition / pressure too high
Bit 4: Unsuitable learn condition / pressure too low
Bit 5: Pressure decreasing instead of rising
Bit 6: Open pressure does not match
Learn Bank 1
xx = 11
Learn Bank 2
xx = 12
Learn Bank 3
xx = 13
Learn Bank 4
xx = 14
Status 0750xx01 SINT8 RO
NV 0 2 0:Not used
1:Avaialable
2:Available with warnings
Data 0750xx02 UINT32 RW
NV To copy learn data copy this content to another
bank (or valve)
Warning Info 0750xx09 UINT16 RO
NV Bit 1: Checksum error
Bit 2: Terminated by user
Bit 3: Unsuitable learn condition / pressure too high
Bit 4: Unsuitable learn condition / pressure too low
Bit 5: Pressure decreasing instead of rising
Bit 6: Open pressure does not match
Type 0750xx0A SINT8 RO
NV 0 2 0:Standard
1:Short
2:Calculated
Delete Learn Bank
Data
0750
xx
0F
BOOL
RW
V
0
1
Set to 1 delete learn bank data.