Operating Instructions
DSGH
®
Radiation-Based Detector with GEN2000
®
Electronics for Density Measurement
Document ID:
31392
Nuclear

Table of Contents

Other manuals for Vega DSGH

Questions and Answers

  • W
    williamsyvetteAug 13, 2025
    What to do if CPU board is not functioning on Vega DSGH Security Sensors?
    • S
      Sandra SimsAug 14, 2025
      If the CPU board LED on your Vega Security Sensors isn't blinking, first ensure the power input is correct. If the issue persists, the CPU board may need to be replaced.
  • J
    Joshua DavisAug 17, 2025
    What to do if memory corruption is indicated by LED on the CPU board of Vega Security Sensors?
    • T
      Todd FloresAug 17, 2025
      If your Vega Security Sensors system shows memory corruption via the LED on the CPU board, run the software diagnostics. If the issue continues, contact VEGA Field Service for assistance.
  • D
    Dennis OrtizAug 21, 2025
    What to do if there is no relay output from Vega Security Sensors power supply board?
    • A
      Albert ReidAug 21, 2025
      If there is no relay output from your Vega Security Sensors power supply board, check the relay output terminals 3, 4, and 5. If there's still no output, the power supply board likely needs replacement.
  • T
    Tom JohnsonAug 25, 2025
    What to do if analog output loop voltage is not present on Vega DSGH?
    • D
      Dustin FrancisAug 25, 2025
      If the analog output loop voltage is absent on the 4 mA ... 20 mA output of your Vega Security Sensors, check the loop wiring and jumpers JP1, JP2 on the power supply board. If the issue persists, consider replacing the power supply board.
  • S
    Shawn AdamsAug 28, 2025
    What to do if CPU LED does not blink on Vega Measuring Instruments?
    • L
      lee61Aug 28, 2025
      If the CPU LED on your Vega Measuring Instruments isn't blinking, indicating the CPU is not functioning, first check the power input. If the issue persists, replace the CPU board.
  • Y
    yjohnsonSep 1, 2025
    What to do if +24V LED is off on Vega Measuring Instruments?
    • D
      Donald VasquezSep 1, 2025
      If the +24V LED is off, indicating that 24 V is not present on the 4 ... 20 mA output and HART communications, check the loop wiring and jumpers JP1, JP2 on the power supply board. If the problem continues, replace the power supply board.
  • C
    Christina OconnellSep 5, 2025
    What to do if relay is off in Vega Measuring Instruments?
    • P
      phensleySep 5, 2025
      If the relay is de-energized, check against relay output terminals 3, 4, and 5. If there is still no relay output, replace the power supply board.
  • J
    Jennifer LeSep 8, 2025
    How to troubleshoot +6V LED being off on Vega Measuring Instruments?
    • W
      Wendy LarsonSep 8, 2025
      If the +6V LED is off, indicating that the electronics are not receiving the +6 V DC required for functioning, verify +6 V on pin 8 of the terminal strip (Pin 9 can be used as a ground reference). Also, check the fuse on the power supply board and the power input terminals 1 and 2.

Summary

Revision History

Preface

Explanation of Symbols

Introduces symbols used in the manual and on the instrument for warnings and indicators.

Your Comments

Provides a section for user feedback and suggestions for manual improvement.

Introduction

Nuclear Materials Notice

Alerts users to the presence of radioactive source material and required licenses for handling.

Unpacking the Equipment

Provides instructions and cautions for safely unpacking the radiation detector equipment.

DSGH Specifications

Details the technical specifications of the DSGH density gauge, including accuracy and power requirements.

Principle of Operation

Explains how the density gauge measures process material density using radiation transmission.

Communicating with the Gauge

Describes methods for connecting and communicating with the gauge using HART or software.

Installation

Testing on the Bench

Guides users on pre-installation testing of the detector assembly with communication devices.

Location Considerations

Provides guidance on selecting an optimal location for the density gauge for accurate measurements.

Wiring the Equipment

Details the procedures for wiring the gauge, including plug replacement and connections.

Power

Covers AC and DC power requirements, input voltage, and connection considerations for the gauge.

Commissioning the Gauge

Outlines the steps involved in commissioning the gauge, including radiation tests and calibration.

Calibration

Current Loop (Analog Output) Calibration

Explains how to calibrate the 4-20 mA current loop output for accurate density readings.

Choosing the Linearizer Type

Discusses selecting the appropriate linearizer type to shape the gauge's response curve for density.

Periodic Standardization

Describes the process of periodic standardization to adjust for drifts and maintain accuracy over time.

Advanced Functions

Gauge Information

Provides access to detailed gauge parameters, serial numbers, and sensor coefficients.

Test Modes

Explains various test modes for troubleshooting, simulating sensor output, and checking functions.

Diagnostics and Repair

Software Diagnostics

Details how the system alerts users to potential problems via messages and status screens.

Troubleshooting

Covers circuit board identification, test points, jumpers, and LED indicators for troubleshooting.

Maintenance and Repair

Outlines the periodic maintenance schedule and procedures for keeping the gauge operational.

Field Repair Procedures

Describes field-replaceable parts like CPU and power supply boards for repairs.

Vega DSGH Specifications

General IconGeneral
BrandVega
ModelDSGH
CategorySecurity Sensors
LanguageEnglish