5 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66190-EN-221107
0 %
100 %
1
2
5
4
3
6
Fig.43:Congurationbypass
1 Radar sensor
2 Polarisation marking
3 Instrumentange
4 Distance sensor reference plane to upper tube connection
5 Distance of the tube connections
6 Ball valve with complete opening
Instructions of orientation of the polarisation:
Note marking of the polarisation on the sensor
Withthreadedversions,themarkingisonthehexagon,withange
versionsbetweentwoangeholes
The marking must be in one plane with the tube connections to the
vessel
Instructions for the measurement:
The 100 % point may not be above the upper tube connection to
the vessel
The 0 % point may not be below the lower tube connection to the
vessel
Min. distance, sensor reference plane to upper edge of upper tube
connection > 200 mm
The antenna diameter of the sensor should correspond to the
inner diameter of the tube
For stand pipe lengths > 3 m the " Application stand pipe > 3 m"
must be selected for the parametrisation
For stand pipe lengths > 3 m, the antenna diameter must be cho-
sen as large as possible, but at least 80 mm/3"
Congurationbypass
Instructions and require-
ments, bypass