39
EN
16657715_en 05/2006
5.2.7 Fault indications (Error):
During operation the essential functions are monitored
and any occurring faults are indicated by a message
on the display. A horn signal also sounds.
The indication flashes on the display until the fault has
been eliminated.
Net not running
Cause: Net roll empty
Net incorrectly fed
Remedial measures: Check net feed
Initiate binding again with
Start
Motor malfunction, Twine binding
Cause: Twine binding not in initial
position
Twine binding motor does not
run
Remedial measures: Reset Twine binding (See
chapter.5.2.6)
Check twine motor
Malfunction net binding linear motor
Cause: Linear motor not in initial
position
Linear motor does not start
Remedial measures: Reset Net binding (See
chapter.5.26)
Check linear motor
o delete the display, eliminate the error and clear the
error message on the display with the start key.
5.3 Pick-up
The pick-up is set as described in Section 4.6. During
use, the pick-up is to be positioned at the preset height
above the feeler wheels on the ground, and the control
unit set to floating position. Optimal and careful crop
pick-up is ensured by following the lie of the ground.
When turning and when picking up extremely large
volumes of crop the travelling speed is to be adjusted
according.