EasyManua.ls Logo

Viessmann B1HF - Page 106

Viessmann B1HF
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
106
Gas boiler, type B and C, category II
2N3P
Type B1KF-26 B1KF-30 B1KF-35
Rated heating output range (details to EN 15502)
T
F
/T
R
= 50/30 °C
Natural gas kW
3.2 (5.7
*4
) -
25.0
3.2 (5.7
*1*4
) -
25.0
3.2 (5.7
*1*4
) -
32.0
LPG kW 3.2 - 25.0 3.2 - 25.0 3.2 - 32.0
T
F
/T
R
= 80/60 °C
Natural gas kW
2.9 (5.2
*1*4
) -
23.0
2.9 (5.2
*1*4
) -
23.0
2.9 (5.2
*1*4
) -
29.3
LPG kW 2.9 - 23.0 2.9 - 23.0 2.9 - 29.3
LPG kW 3.0 - 23.4 3.0 - 23.4 3.0 - 29.9
Rated heat input for DHW heating (Qnw)
Natural gas kW
3.0 (5.3
*1*4
) -
26.5
3.0 (5.3
*1*4
) -
30.6
3.0 (5.3
*1*4
) -
35.3
LPG kW 3.0 - 26.5 3.0 - 30.6 3.0 - 35.3
Product ID CE-0085DL0217
IP rating to EN 60529 IP X4 to EN 60529
Gas supply pressure
Natural gas mb
ar
kPa
20
2
20
2
20
2
LPG mb
ar
kPa
50
5
50
5
50
5
Max. permiss. gas supply pressure
*5
Natural gas mb
ar
kPa
25.0
2.5
25.0
2.5
25.0
2.5
LPG mb
ar
kPa
57.5
5.75
57.5
5.75
57.5
5.75
Sound power level
(to EN ISO 15036-1)
At partial load dB(
A)
31.9 31.9 31.9
At rated heating output (DHW heating) dB(
A)
49.1 50 50.4
Power consumption
(in the delivered condition)
W 45 64 110
Rated voltage V 230
Rated frequency Hz 50
Appliance fuse protection A 4
Backup fuse (power supply) A 16
Communication module (integral)
WiFi frequency band MH
z
2400 - 2483.5
*4
Appliances for multiple connection of type B1HF-[kW]-M and B1KF-[kW]-M
*1
Appliances for multiple connection of type B1HF-[kW]-M and B1KF-[kW]-M
*5
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor up-
stream of the system.
Specification
Specification (cont.)
6167586
Service

Table of Contents

Related product manuals