EasyManua.ls Logo

Viessmann B1HF - Removing the Hydraulic Unit

Viessmann B1HF
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
4. Remove gaskets and dispose of them.
5. Check connections on the DHW side for scaling.
Clean or replace the plate heat exchanger as
required.
6. Check connections on the heating water side for
contamination. Clean or replace the plate heat
exchanger as required.
7. Install plate heat exchanger in reverse order using
new gaskets.
Tighten screws as tightly as necessary and ensure
that the components are undamaged and are func-
tioning correctly throughout service life.
Observe torque settings if a torque wrench is avail-
able.
Screw torque: 3.2 Nm
±
0.2
Note
During installation, ensure the connections are
positioned and the gaskets seated correctly.
Danger
Risk of electric shock from escaping heating
water or DHW.
Check all water side connections for tight-
ness.
Removing the hydraulic unit
If components of the hydraulic unit have to be
replaced.
Danger
Risk of electric shock from escaping heating
water or DHW.
After installation, check all connections on the
water side for leaks.
Troubleshooting
Repairs (cont.)
6167586
Diagnosis

Table of Contents

Related product manuals