Viessmann B1HF - Repairs and Component Servicing Procedures; Boiler Shutdown and Isolation for Repairs

Viessmann B1HF
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82
!
Please note
Residual water will escape when the boiler or
one of the following components is fitted or
removed:
Water-filled pipework
Heat exchanger
Circulation pumps
Plate heat exchanger
Components fitted in the heating water or
DHW circuit.
Water ingress can result in damage to other
components.
Protect the following components against
ingress of water:
Control unit components (especially in the
service position)
Electrical components
Plug-in connections
Cables and leads
Shutting down the boiler
1. Turn off the power supply at the ON/OFF switch.
2. Shut off the gas supply.
3. If the boiler needs to be removed:
Isolate the system from the power supply, e.g. by
removing the separate fuse or by means of a
mains isolator, and check that it is no longer live.
Safeguard the system against reconnection.
Disconnect the balanced flue system.
Drain the boiler on the heating water and DHW
sides.
Disconnect the on-site cables/leads.