Viessmann VITOCAL Series - Floorstanding installation with support, line entry above ground level

Viessmann VITOCAL Series
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Single row layout
> 500
A
400
B
A
B
A
B
> 500 > 500 > 500
A
B
> 500
A
B
> 500
A
Air intake
B
Air discharge
Siting information
■ Observe the information regarding noise levels.
■ Sound emission (TA-Lärm) regulations must be observed [in Ger-
many].
■ When siting the heat pump, always take into account the distances
to neighbouring property in accordance with local building regula-
tions.
■ During defrosting, cool vapour escapes from the outdoor unit air
discharge vents. This vapour discharge must be taken into consid-
eration during installation (choosing the installation location, orien-
tation of the heat pump).
Floorstanding installation with support, line entry above ground level
3000
A
200
300
K
702
835
E
F
1100
C D
200
L
B
G
H
500
180
A
Ground
B
Pathway, patio
C
Hydraulic connection lines, indoor/outdoor unit
D
Indoor/outdoor unit Modbus cable and outdoor unit power cable:
Route the cables so they are not stressed.
E
Openings in the base plate for free drainage of condensate:
Never seal the openings.
F
Connection set, wall mounting (accessories)
G
Support for floorstanding installation (accessories)
H
Foundation strip
K
Frost protection for foundations (compacted crushed stone, e.g.
0 to 32/56 mm); thickness of layer subject to local requirements
and building regulations
L
Flexible separating layer between the foundations and the build-
ing
Note
Provide thermal insulation of sufficient thickness on the pipework to
the outdoor air: See table on page 99.
Design information
(cont.)
102
VIESMANN
VITOCAL