Specification
Power supply Via KM-BUS
Power consumption 0.2 W
Protection class III
IP rating IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation 0 to +40 °C
– Storage and transport −20 to +65 °C
Setting range of the set
room temperature for
standard mode 3 to 37 °C
Notes
■ If the Vitotrol 200-A is to be used for room temperature hook-up,
site the device in a main living room (lead room).
■ Connect maximum 3 Vitotrol 200-A units to the control unit.
9.4 Wireless remote control units
Information on Vitotrol 200-RF
Wireless remote control unit with integral wireless transmitter for
operation with the wireless base station.
A Vitotrol 200-RF can be used for each heating or cooling circuit.
The Vitotrol 200-RF can operate one heating/cooling circuit.
Up to 3 wireless remote control units can be connected to the control
unit.
Note
The wireless remote control unit cannot be combined with a hard-
wired remote control.
Vitotrol 200-RF
Part no. Z011219
Wireless subscriber
■ Displays:
– Room temperature
– Outside temperature
– Operating condition
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture)
Note
The set room temperature for reduced mode (reduced room
temperature) is set at the control unit.
– Operating program
■ Party and economy mode can be enabled via keys
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation location:
■ Weather-compensated mode:
Installation anywhere in the building
■ Room temperature hook-up:
The integral room temperature sensor captures the room tempera-
ture and effects any necessary correction of the flow temperature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators
– Not on shelves or in recesses
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct insolation, fireplace, TV set, etc.)
Note
Observe the "Wireless accessories" technical guide.
Specification
Power supply 2 AA batteries 3 V
Radio frequency 868 MHz
Wireless range See "Wireless accessories" technical
guide
Protection class III
IP rating IP 30 to EN 60529; ensure through de-
sign/installation
Permissible ambient temperature
– Operation 0 to +40 °C
– Storage and transport −20 to +65°C
Setting range of the set
room temperature for
standard mode 3 to 37 °C
Control unit accessories
(cont.)
138
VIESMANN
VITOCAL
9
5831388