Vitocal 200-A, 230 V appliances
Type
´
min
in l/h 7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWO-M
– AWO-M-E
– AWO-M-E-AC
201.A04 700 DN 25 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A06 700 DN 25 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A08 700 DN 25 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A10 1400 DN 32 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A13 1400 DN 32 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A16 1400 DN 32 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Vitocal 200-A, 400 V appliances
Type
´
min
in l/h 7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWO
– AWO-E
– AWO-E-AC
201.A10 1400 DN 32 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A13 1400 DN 32 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
201.A16 1400 DN 32 50 X Vitocell 100-E
46 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Heating water buffer cylinder in the heat pump return
(connected in series)
Icons:
X Possible
´
min
Minimum flow rate, secondary circuit
7
pipes
Minimum diameter of pipes in secondary circuit
V
min
Minimum volume of the heating system
Underfloor heating circuit
Radiator heating circuit
Vitocal 222-A, 230 V appliances
Type
´
min
in l/h 7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWOT-M-E
– AWOT-M-E-AC
221.A04 700 DN 25
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A06 700 DN 25
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A08 700 DN 25
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A10 1400 DN 32
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A13 1400 DN 32
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A16 1400 DN 32
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Vitocal 222-A, 400 V appliances
Type
´
min
in l/h 7
pipes
V
min
in l
*20
Without buf-
fer cylinder
Buffer cylinder (recommended minimum)
+
– AWOT-E
– AWOT-E-AC
221.A10 1400 DN 32
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A13 1400 DN 32
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
221.A16 1400 DN 32
40
*21
/50
X Vitocell 100-E
40 l
Vitocell 100-E
200 l
Vitocell 100-E
200 l
Heating water buffer cylinder in the heat pump return
(connected in series)
Icons:
X Possible
´
min
Minimum flow rate, secondary circuit
7
pipes
Minimum diameter of pipes in secondary circuit
V
min
Minimum volume of the heating system
Underfloor heating circuit
Radiator heating circuit
*20
Cannot be fitted with shut-off devices
*21
In conjunction with Vitocell 100-E, type SVPA, part no. ZK03801
Design information
(cont.)
VITOCAL
VIESMANN
121
5831388
7

Table of Contents