RP-610 PG2
D-302758 37
6. MAINTENANCE
Note: Battery replacement should be done by a service man.
TURN & PUSH
BATTERY
BATTERY CABLE
BATTERY
SELF-TEST BUTTON
CONNECT THE WIRES
TO THE TERMINAL BLOCK
ENROLL BUTTON
AC CONNECTOR
TERMINAL BLOCK
BATTERY PACK
CONNECTOR
Figure 4 - Battery Pack Insertion
7. LOCAL DIAGNOSTICS TEST
Before testing, separate the base from the cover (see Fig. 2).
A. Press the self-test button once and release it:
The red LED and then the green LED will switch ON and then OFF in turn to indicate that the repeater is now
fully operational.
B. After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength indication.
LED response Reception
Green LED blinks Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you
receive a "poor" signal from the device, re-locate it and re-test until a "good" or "strong" signal strength is
received.