RP-610 PG2 
D-302758  37 
6. MAINTENANCE 
Note: Battery replacement should be done by a service man. 
TURN & PUSH
BATTERY
BATTERY CABLE
BATTERY
SELF-TEST BUTTON
CONNECT THE WIRES
TO THE TERMINAL BLOCK
ENROLL BUTTON
AC CONNECTOR
TERMINAL BLOCK
BATTERY PACK
CONNECTOR
 
Figure 4 - Battery Pack Insertion 
7. LOCAL DIAGNOSTICS TEST 
Before testing, separate the base from the cover (see Fig. 2). 
A.  Press the self-test button once and release it: 
The red LED and then the green LED will switch ON and then OFF in turn to indicate that the repeater is now 
fully operational. 
B.  After 2 seconds the LED blinks 3 times.  
The following table indicates received signal strength indication. 
LED response  Reception  
Green LED blinks  Strong  
Orange LED blinks  Good  
Red LED blinks  Poor  
No blinks  No communication 
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you 
receive a "poor" signal from the device, re-locate it and re-test until a "good" or "strong" signal strength is 
received. 
Note: For detailed Diagnostics Test instructions refer to PowerMaster-10 Installer Guide.