SR-730 PG2
D-302758 43
Here you determine whether or not the siren alone will sound a tamper
alarm when there is no communication between the siren and the control
panel.
26.
27.
or
Select between "Disabled" and "Enabled".
28.
When exiting "
ZONES / DEVICES
" menu, the PowerMaster-10 system
displays the number of devices that need to be updated, as follows: DEV
UPDATING NNN.
For detailed instructions on Adding Devices, Deleting Devices, Replacing
Devices and Defining Defaults see the PowerMaster-10 Installer Guide.
6. LOCAL DIAGNOSTICS TEST
Before testing, remove the plastic cover and then open the battery cover (see Fig. 3).
A. Press the self-test button once and release it; the following procedure should occur in turn:
The red LED will switch ON and then OFF, the green LED will switch ON and then OFF, the strobe light will
switch ON and then OFF and the piezo siren will sound to indicate that the siren is now fully operational.
B. After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength indication.
LED response Reception
Green LED blinks Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you
receive a "poor" signal from the device, re-locate it and re-test until a "good" or "strong" signal strength is
received.
Note: For detailed Diagnostics Test instructions refer to PowerMaster-10 Installer Guide.
A
UTO TAMPER ALRM
D
isabled
A
UTO TAMPER ALRM