4. PROGRAMMING
24 D-305735 PowerMaster 360 Installer's Guide
4.5 Control Panel
4.5.1 General Guidance "Control Panel" Flow-Chart & Menu Options
The "CONTROL PANEL" menu enables you to configure and customize the operation of the control panel. The
"CONTROL PANEL" menu provides you with configurable parameters divided into several groups, each dealing with
certain aspects of the system operations as follows (see detailed list in Step 2 of the chart below):
Group
Description of Group Features and Parameters
Section
Arming/Disarming
and Exit/Entry
Procedures
Contains configurable features and parameters related to Arming and Disarming of the
system and the Exit and Entry procedures.
4.5.2
Zone Behavior
Contains configurable features and parameters related to the functionality of the Zones.
4.5.3
Alarms &
Troubles
Contains configurable features and parameters related to initiating, canceling and
reporting of Alarm and Trouble events.
4.5.4
Sirens
Contains configurable features and parameters common to all sirens in the system.
4.5.5
User Interface
Contains configurable features and parameters related to the functionality of the panel's
audible and visual indications.
4.5.6
Jamming &
Supervision
Contains configurable features and parameters related to detecting and reporting of RF
Jamming and device Supervision (missing device) events.
4.5.7
Miscellaneous
Contains a variety of other configurable features and parameters related to the system.
4.5.8
To enter the "03.CONTROL PANEL" menu and to select and configure an option, proceed as follows:
Step 1 Step 2 Step 3
Select "CONTROL PANEL"
option
Select the "Control Panel" Parameter you wish to configure
Configure
option
See
See
See
INSTALLER MODE
4.5.2
4.5.4
4.5.6
03.CONTROL PANEL
01:ENTRY DELAY1
31:PANIC ALARM
53:MEMORY PROMPT
Go to the
indicated
group
section of
the
selected
option
02:ENTRY DELAY2
32:DURESS ALARM
54:LOW-BAT ACK
03:EXIT DELAY
33:INACTIVE ALRT
56:SCREEN SAVER
04:EXIT MODE
34:TAMPER ALARM
05:QUICK ARM
35:AC FAIL REPRT
06:BYPASS ARM
36:CONFIRM ALARM
07:LATCHKEY ARM
37:ABORT TIME
08:DISARM OPTION
38:CANCEL ALARM
09:ARMING KEY
39:ALARM RESET
40:ABORT FIRE T.
4.5.3
4.5.5
4.5.7
21:SWINGER STOP
61:JAM DETECT
When
done
to
Step 2
22:CROSS ZONING
44:SIREN TIME
62:MISSING REPRT
45:STROBE TIME
63:NOT READY
64:MISS/JAM ALRM
65:SMOK FAST MIS
4.5.8
91:USER PERMIT
93:SOAK PERIOD
Arming &
Disarming
Alarms &
Troubles
User
Interface
Zone
Behavior
Sirens
Jamming and
Supervision
Miscellaneous

Table of Contents

Other manuals for Visonic PowerMaster 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMaster 360 and is the answer not in the manual?

Visonic PowerMaster 360 Specifications

General IconGeneral
BrandVisonic
ModelPowerMaster 360
CategorySecurity System
LanguageEnglish

Related product manuals