APPENDIX D. Specifications
76 D-305735 PowerMaster 360 Installer's Guide
APPENDIX D. Specifications
D1. Functional
1 master installer (9999 by default)*
• 1 installer (8888 by default)*
• 1 master user, no. 1 (1111 by default)
• Users nos. 2 – 8
• Latchkey users 5 - 8
* Codes must not be identical
Virtual keypad, wireless keyfobs and keypads
AWAY, HOME, AWAY-INSTANT, HOME-INSTANT, FORCED, BYPASS.
Silent, personal panic/emergency, burglary, gas (CO), and fire.
External Siren (bell) Timeout
Programmable (4 min. by default)
Programmable time frame for inactivity alert
- Diagnostic test and event log.
- Local and Remote Programming over Broadband and GPRS IP connections.
- Calling for help by using an emergency transmitter.
- Tracking inactivity of people.
Alarm memory, trouble, event log
The control panel keeps and displays time and date. This feature is also used for the
log file by providing the date and time of each event
160 ft. (50 m) internal, 6500 ft. (2000 m) external
• DC Power Jack
• RJ-45 Ethernet Connector
• Micro USB Connector
Internal:
• SIM Card Slot (part of GPRS Module)
• Micro SD Card Slot
• Battery Backup Connector
PowerG – 2-way synchronized Frequency Hopping (TDMA / FHSS)
North America and
selected countries
2.4 GHz. Access Point is for IP camera support only
1
Covered by Module 2
2
Covered by Module 1