7. READING THE EVENT LOG
56 D-305735 PowerMaster 360 Installer's Guide
7. READING THE EVENT LOG
Up to 100 events are stored in the event log. You can access this log and review the events, one by one. If the event
log fills up completely, the oldest event is deleted upon registration of each new event. The
date and time of occurrence
are memorized for each event.
Note: Up to 250 events are stored in the event log that can be reviewed via the Remote Programmer PC software
application or by the remote PowerManage server.
When reading the event log, events are shown in chronological order - from the newest to the oldest. Access to the
event log is provided by clicking the button and not through the Installer Mode menu. The reading and erasing
process of the event log is shown below.
Step 1
Step 2
Step 3
Step 4
In normal operating
mode
[1] Enter Installer Code [2] Reviewing Events
[3] Scroll List of Events [4]
READY 00:00
ENTER CODE:
Z13 alarm
SR2 TAMPER-ALARM
LIST OF EVENTS
09/02/11 3:37 P
07/02/11 11:49 a
Step 5
Step 6
Step 7
Step 8
CLEAR EVENT LOG
display
[5]
Erase the Event Log
[6]
Event Log is erased
[7]
Returns to normal
operating mode
[8]
CLEAR EVENT LOG
<OFF> to delete
<OK> TO EXIT
READY 00:00
- Reading Events
[1]
While the system is in the normal operating mode, press the key.
Reading the Event Log
[2]
Enter the current Installer Code and then press to enter "LIST OF EVENTS".
[3]
The latest event is shown.
The event is displayed in two parts, for example, "Z13 alarm" then "09/02/10 3:37 P".
Note: In Soak Test mode, the panel displays the alarmed zone and alternates with “Zxx:Soak T.Fail”.
[4]
Press repeatedly to scroll through the list of events.
Erasing and Exiting the Event Log:
[5]
From anywhere within the event log, press the button and then press .
[6]
At this stage in the procedure, clicking the or buttons will take you to “<OK> TO EXIT
without erasing the event log. Clicking the button will revert to “CLEAR EVENT LOG”.
Press the button to erase the event log.
[7]
The system erases the event log
[8]
Press to revert to normal operating mode.
Clicking the button repeatedly at any stage in the procedure takes you one level up with each click.
Clicking the button will take you to “<OK> TO EXIT”.

Table of Contents

Other manuals for Visonic PowerMaster 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMaster 360 and is the answer not in the manual?

Visonic PowerMaster 360 Specifications

General IconGeneral
BrandVisonic
ModelPowerMaster 360
CategorySecurity System
LanguageEnglish

Related product manuals