4. PROGRAMMING
50 D-305735 PowerMaster 360 Installer's Guide
Option
Configuration Instructions
10:ABORT TIME
The PowerMaster 360 can be configured to provide a delay before reporting an alarm to the
monitoring station (not applicable to alarms from FIRE, 24H SILENT and EMERGENCY
zones). During this delay period, the siren sounds but the alarm is not reported. If the user
disarms the system within the delay time, the alarm is aborted. You can activate the feature
and select the "Abort Time" interval.
Options: in 00 (default in USA)/15/30(default)/45/60 seconds; in 2/3/4 minutes
11:CANCEL ALARM
The PowerMaster 360 can be configured to provide a ”Cancel Alarm” time window that starts
upon reporting an alarm to the Monitoring Station. If the user disarms the
system within that
"cancel alarm" time, a “cancel alarm” message is sent to the Monitoring Station indicating that
the alarm was canceled by the user.
Options: not active (default in USA); in 1/5 (default)/15/60 minute(s) and in 4 hours.

Table of Contents

Other manuals for Visonic PowerMaster 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic PowerMaster 360 and is the answer not in the manual?

Visonic PowerMaster 360 Specifications

General IconGeneral
BrandVisonic
ModelPowerMaster 360
CategorySecurity System
LanguageEnglish

Related product manuals