5.Panel Operation
parameter value of low level. Turn the knob to change the value directly, or
use the numeric keypad to input the desired value and choose the unit.
Set the Phase
Press the Phase softkey, the Phase menu item is highlighted. In Parameter 4
of Figure 5-2, a blinking cursor appears in the parameter value of Phase. Turn
the knob to change the value directly, or use the numeric keypad to input the
desired value and choose the unit.
Output Square Wave
Press , the screen displays the user interface of the square wave. The
Square waveform parameters can be set by operating the Square setting
menu on the right.
The square wave menu includes: Frequency/Period, Amplitude/High Level,
Offset/Low Level, and Phase.
To set the Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase,
please refer to Output Sine Wave on page 6.
Load
Output
switch
Parameter 1
Parameter 2
Parameter 3
Parameter 4
Square
Period
High low
- level
Channel
Current
signal
Setting menu of
Square signal
Figure 5-4: Square wave user interface
Output Ramp Wave
Press , the screen displays the user interface of the ramp wave. The
Ramp waveform parameters can be set by operating the Ramp setting menu
on the right.
The ramp menu includes: Frequency/Period, Amplitude/High Level,
Offset/Low Level, Phase, and Symmetry.
To set the Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase,
please refer to Output Sine Wave on page 6.