26-6 Sea Water System, Sea Water Pump
Seawater Pump, Impeller, Change
Closed sea cock
1
Unscrew all screws on the cover (1
).
2 Remove the impeller (1) with the aid of pliers.
3 Clean the pump housing and sealing surfaces.
4 Lubricate the impeller and housing with glycerin.
Place the impeller and a new gasket in the hous-
ing.
Screw the cover down.
Open the sea cock and start the engine. Check
the sealing.
IMPORTANT!
Only glycerin may be used as an impeller lubricant.
26-6 Sea Water System, Sea Water Pump
120 47701798 05-2013 © AB VOLVO PENTA