9.2.7 Expert parameters
As the last parameter setting dene the parameters in the Expert parameters window.
Expert parameters are available for special applications:
To do this, activate the Display expert parameters function in the window Parameter under the
moduleconguration tab.
Ö The Expert parameters window appears.
You have the following options:
Temperature warning:
If internal sensors are used, a warning message can be given out when the dened temperature
value is exceeded. 100 °C is dened as default here (maximum value: 115 °C).
Tire status messages:
Here the transmission of trailer data in the towing vehicle and the transmission of the vehicle
conguration can be deactivated. The latter can be useful for telemetry congurations.
With external sensors, the temperature transmission can be deactivated.
Tire pressure limit values:
Here the setpoint pressures that can be set in the module conguration can be restricted when
using the driver conguration (only for OE vehicles).
Lifting axle positions:
To prevent the monitoring of non-moving wheels (which, in the worst case, can result in a sensor
not being received) with lifting axles, the corresponding axles can be selected here.
CANconguration:
Here the CAN bus baud rate can be adjusted.
After the data is written to the ECU, diagnosis needs to be re-established.
CAN termination:
For an integration in an existing CAN bus or with a trailer train conguration it may be necessary
to deactivate the CAN termination, which is activated by default.
In addition, you can dene whether the CAN termination should remain activated in sleep and
listen mode.
Increased power consumption with ignition off if the CAN termination is activated with sleep
and listen mode.
Reset and leakage parameter:
If activated, another page displays the parameters for resetting the leakage algorithm are
displayed.
DM1 message:
These parameters dene the conditions for sending DM1 messages and whether they should be
empty (no event present) or lled (event present) in a fault-free state.