70
Operation
Operation
System failure
A system failure has occurred if display shows crossed-out "IVTM". OptiTire does not signal warning
messages for any wheel. The driver must check the tire pressures manually on the wheel.
System error
Repair note
Check the supply voltage of the ground line.
Check the cable connections.
Carry out a system diagnostics.
Battery warning
If the wheel sensor battery’s end of life has been reached after around 9 years, a battery warning is set
around half a year beforehand. This is indicated in the display by a ashing sensor and a corresponding
battery symbol. No warning lamp is indicated.