EasyManuals Logo

Wacker Neuson RC70 User Manual

Wacker Neuson RC70
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
Maintenance
Electrical system
150
BA RC50_RC70 en 00
Check the battery open-circuit voltage (must be at least 11.9 V) with
suitable means, and recharge if necessary.
a
Full starter power.
External charging
NOTE
Deeply discharged batteries must be removed from the
machine for recharging.
Observe the manufacturer's specifications for charger and
battery during every charging work step.
Do not charge the battery unless in a well ventilated room.
Remove the battery from the machine.
Before recharging, ensure that the battery degassing is intact.
Before charging, check the electrolyte level and correct if necessary.
Connect the battery charger according to the manufacturer's
specifications, and then start recharging.
Always watch the charging process and stop charging when the acid
temperature exceeds 55 °C or in case of acid spill.
a
Battery charged.
Switch off and disconnect the charger from the battery.
If necessary, remount the battery.
a
Battery is ready for use.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RC70 and is the answer not in the manual?

Wacker Neuson RC70 Specifications

General IconGeneral
BrandWacker Neuson
ModelRC70
CategoryTrash Compactor
LanguageEnglish

Related product manuals