43
VERSION 01/2018
ORDER NUMBER DOC 2340851
Cobra 40-10 / 40-25
8.2.9.3 VENT
B_04243
A5
X
B_04247
9
1
5
Procedure
1. Turn the pump upside down. Remove the threaded plug (5).
2. Slowly start up the pump (vent), until no more air bubbles rise from the oil intake
tube.
3. Oil level A in the oil tank has to be within the specied markings (X).
4. Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
5. Mount piston cover (1) and hood with casing.
6. Return device to correct setup position.
7. The device is ready for operation again.