VERSION 01/2018
ORDER NUMBER DOC 2340851
Cobra 40-10 / 40-25
10 REPAIR WORK
10.1 REPAIR STAFF
Repair work must be carried out carefully and by qualied and trained personnel. They
should be informed of specic hazards during their training.
The following hazards may arise during repair work:
Health hazard from inhaling solvent vapors.
Use of unsuitable tools and aids.
A skilled person must check to ensure that the device is in a reliable state after it is repaired.
Carry out function test in accordance with Chapter 11.
10.2 REPAIR NOTES
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may carry out repairs and
replace parts.
Use only WAGNER original spare parts and accessories.
Only repair and replace parts that are listed in the "Spare parts" chapter and that are
assigned to the unit.
Before all work on the device and in the event of work interruptions:
- Relieve the pressure from the spray gun, high-pressure hoses and all devices.
- Secure the spray gun against actuation.
– Switch o the energy and compressed air supply.
- Disconnect the control unit from the mains.
Observe the operating and service manual for all work.
Before a Repair
Flush and clean the system. Section 8.1.2
The air supply should be interrupted.
After a Repair
Carry out safety checks in accordance with Chapter 8.2.3.
Put the system into operation in accordance with Chapter 6.7 and check for leaks in
accordance with Chapter 11.
Function test in accordance with section 11.
10.3 TOOLS
The following tools are required for carrying out the repair work described below on the
Cobra pump:
Open-end wrenches, size 3; 5; 7; 8; 10; 12; 13; 14; 15; 16; 17; 18; 19; 22; 24; 27; 36; 50.
Allen wrench, size 10.
Screwdriver, size 3.
Torque wrench 40 Nm; 29.5 lbft.

Table of Contents

Other manuals for WAGNER Cobra 40-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER Cobra 40-10 and is the answer not in the manual?

WAGNER Cobra 40-10 Specifications

General IconGeneral
BrandWAGNER
ModelCobra 40-10
CategoryWater Pump
LanguageEnglish

Related product manuals