Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
4 Basic Safety Instructions
Order number 2340851 | Edition 05/2022 17
4 Wear static dissipative gloves when spraying. The grounding takes place via the spray
gun's handle or its trigger.
4.2.4 Product Hoses
Danger due to bursting of product hose!
The product hose is under pressure and may cause dangerous injuries.
4 Ensure that the hose material is chemically resistant to the sprayed products and the
flushing agents used.
4 Ensure that the product hoses and the fittings are suitable for the pressure generated.
4 Ensure that the following information can be seen on the high-pressure hose:
4 Manufacturer
4 permissible operating pressure
4 Date of manufacture
4 Make sure that the hoses are laid only in suitable places. Hoses should not be laid in the
following places under any circumstances:
4 in high traffic areas
4 on sharp edges
4 on moving parts
4 on hot surfaces
4 Ensure that the hoses are never run over by vehicles (e.g., fork lifts), or that the hoses
are never put under pressure from the outside in any other way.
4 Ensure that the hoses are never kinked. Observe maximum bending radii.
4 Ensure that no work is ever performed with a damaged hose.
4 Make sure that the hoses are never used to pull or move the device.
4 The electrical resistance of the product hose, measured at both valves, must be less
than 1 MΩ.
4 Suction hoses may not be subjected to pressure.
4.2.5 Cleaning and Flushing
Danger due to cleaning and flushing!
Explosion hazard and damage to the device.
4 Non-ignitable cleaning agents and flushing agents should preferably be used.
4 When carrying out cleaning work with flammable cleaning agents, make sure that all
equipment and resources (e.g., collection tank, funnel, transport cart) are conductive or
static dissipative and grounded.
4 Observe the specifications of the lacquer manufacturer.
4 Ensure that the flash point of the cleaning agent is at least 15 K above the ambient
temperature or that cleaning is undertaken at a cleaning station with technical
ventilation.
4 Never use chloride or halogenated solvents (such as trichloroethane and methylene
chloride) with devices containing aluminium or galvanized/zinc-plated parts. They may
react chemically thus producing an explosion danger.
4 Take measures for workplace safety.

Table of Contents

Other manuals for WAGNER Cobra 40-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER Cobra 40-10 and is the answer not in the manual?

WAGNER Cobra 40-10 Specifications

General IconGeneral
BrandWAGNER
ModelCobra 40-10
CategoryWater Pump
LanguageEnglish

Related product manuals