Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
5 Description
Order number 2340851 | Edition 05/2022 23
Description Units Cobra
40-10
Cobra
40-25
Weight kg; lb 19; 41.9 33; 72.8
Product pH value pH 3.5 – 9
Maximum product pressure at pump inlet MPa
bar
psi
2
20
290
Product temperature °C
°F
10 – 80
50 – 176
Ambient temperature - Assembly and operation °C
°F
10 – 60
50 – 140
Ambient temperature - Storage °C
°F
-20 – 60
-4 – 140
Relative humidity % 10–95 (without conden-
sation)
Allowable inclination for operation ∠° ± 10
Hydraulic oil filling amount (approximate) L
cu inch
0.110
6.71
0.130
7.93
* Measured A-rated emission sound pressure level at distance of 1m, LpA1m in accordance
with DINEN14462: 2015. Reference measurements have been made by Suva (Swiss National
Accident Insurance Fund).
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
4 Provide compressed air free from oil and water.