Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
8 Cleaning and Maintenance
48 Order number 2340851 | Edition 05/2022
8.2.8.3 High-pressure filter
B_05427
12
11
10
7
2
3
5
1
21
80 **
81
82 **
53 MPa
530 bar
7687 psi
27 MPa
270 bar
3916 psi
A
B
A Preferred filter installation position B Reversed filter installation position
80 Mobilux EP2** 82 Anti-seize paste**
81 Filter identification
1. Flush the pump and HP filter in accordance with Chapter Basic Flushing [839], and
while doing so:
4 At the preferred filter installation position: Flush via the return valve (1). This
produces a large flow. As a result, the flushing agent also flows through the upper
part of the filter cartridge (11). Pressure regulator approx. 0.15MPa; 1.5bar; 22psi.
4 With a reversed filter installation position: Flush using the spray gun. This is
required in the case of a reversed installation position so that the flushing agent
flows through the filter cartridge (11). Maximize the flow (remove the nozzle, open
the dosing valve if necessary).

Table of Contents

Other manuals for WAGNER Cobra 40-10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER Cobra 40-10 and is the answer not in the manual?

WAGNER Cobra 40-10 Specifications

General IconGeneral
BrandWAGNER
ModelCobra 40-10
CategoryWater Pump
LanguageEnglish

Related product manuals