8 Cleaning and Maintenance
Order number 2340851 | Edition 05/2022 53
8.2.11.3 Vent
B_07988
A
5
X
9
1
5
1. The dismounted pump is to be place upside down on a suitable underlay and positioned
horizontally. Remove the threaded plug (5).
2. Slowly start up the pump (vent), until no more air bubbles rise from the oil suction tube.
3. Oil level A in the oil tank has to be within the specified markings X.
4. Screw in threaded plug (5) and tighten with 2 Nm; 1.5 lbft.
5. Mount piston cover (1) and hood with casing.
6. Return pump to correct setup position.
7. Pump is ready for use again.