SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
Powder quantity increase / decrease (over the same protocol)
The control unit must be in coating mode (not standby, not ush, not con guration menu,
not when starting the unit, etc.).
The C16 setting parameter must be set to "on" in the "Service" con guration menu.
– Increase powder quantity by 1% Transfer "Recipe number" 51
– Reduce powder quantity by 1% Transfer "Recipe number" 52
If one of the two commands was detected and performed, the control unit changes to the
powder quantity selection. The change only a ects the temporary powder quantity set
point and is not stored in EEPROM. Saving must be done using the program buttons. The
two commands can be called several times successively to increase the powder quantity,
for example by 5%.
Carry out spray current reset one time (using the same protocol)
(only for EPG-SPRINT X software version 210 or later)
High voltage must not be switched on when calling up the command. A blocking period
of 10 seconds also takes a ect after switching o the high-voltage manual. The command
is not run during this blocking period.
There is no feedback as to whether the reset was run successfully.
– Run spray current reset one time Transfer "Recipe number" 63
Attention:
The higher-level controller must ensure that no high-voltage module was switched on in
the system 10 seconds before calling up the command!
The exact application is described in more detail in the appendix of the EPG-SPRINT X
operating manual.