29
B_00304
R max < 1 M:
OPERATING MANUAL
VERSION 12/2015
ORDER NUMBER DOC2333558
6.5 GROUNDING
Grounding scheme (example)
Paint tank
Work piece
Conveyor
Spraying stand
Floor, static dissipative
Heavy paint mist if grounding is insu cient!
Danger of poisoning.
Insu cient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic sparks.
Clean the piston pump only with a damp cloth.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Cable cross sections
Pump 4 mm; Conveyor 16 mm;
Product tank 6 mm; Booth 16 mm;
Spraying stand 16 mm;