54
ProfiTech M
P_02179 P_02180
OPERATING MANUAL
VERSION 07/2014 ORDER NUMBER DOC 2335144
7.10.1 SIGNALS ON THE EPGSPRINT X
A maximum of two EPG Sprint X for manual guns can be connected.
This connection makes the release and ush function available.
The connection takes place with the connection cable (Order No. 2335605).
This cable can also be used to lengthen an identical cable in 10m; 32.81 ft increments.
7.10.2 PARAMETER SETTING ON THE EPGSPRINT X
For the control of the manual guns, the C26 parameter "Operating mode for manual gun
with external control" must be set in the con guration menu to value "1" or "2".
In case of replacing the control unit this parameter must be set again on the new control
unit.
The parameter and the entry into the con guration menu are described in the service
manual of the EPG-Sprint X control unit.