EasyManua.ls Logo

WAGNER ProfiTech M - CONNECTING SPRAY GUN BLOW OUT FIXTURE; Connecting Spray Gun Blow Out Fixture

WAGNER ProfiTech M
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
83
ProfiTech M
P_02454
OPERATING MANUAL
VERSION 07/2014 ORDER NUMBER DOC 2335144
7.15.5 CONNECTING SPRAY GUN BLOW OUT FIXTURE
The spray gun blow out  xture is controlled via the HU1 sliding table.
It must be connected before the sliding table assumes its  nal position.
Fit the sliding table at a distance of 10 cm from the booth wall to provide access to the face
end for servicing.
1. Dismount front panel on sliding table.
2. Pull out cable on front with valve plug and plug valve
plug onto solenoid valve.
3. Re t front cover on sliding table.

Table of Contents

Related product manuals