ProfiTech M
OPERATING MANUAL
VERSION 07/2014 ORDER NUMBER DOC 2335144
5. Press " " key, the "Selection con rmation" symbol is
displayed with a bright background to the left of the
"Alignment"  eld.
Either the "Reject selection" function or "Return to
selection menu" function is set by pressing the "
"
key.
The set function is adopted by pressing the " " key.
6. Press "
" key, two bar graph  elds display the
alignment status of the  rst beam (FB = First Beam)
and last beam (LB = Last Beam).
Both bar graph  elds must be completely  lled.
7. To align the light curtains, loosen fastening screws on
transmitter and receiver and align transmitter and
receiver with one another.
8. Once aligned, retighten fastening screws of
transmitter and receiver.
9. Once the alignment operation is complete, go back
to the measurement operation.